Description
Environmental Conditions
Operating temperature | -40°C to +85°C |
Calibration temperature | 20…28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree (encl./terminal) | IP68 / IP00 |
Mechanical specifications
Dimensions | Ø 44 x 20.2 mm |
Weight approx. | 50 g |
Wire size | 1 x 1.5 mm2 stranded wire |
Screw terminal torque | 0.4 Nm |
Vibration | IEC 60068-2-6 |
2…25 Hz | ±1.6 mm |
25…100 Hz | ±4 g |
Common specifications
Supply |
|
Supply voltage | 8.0…35 VDC |
Internal power dissipation | 25 mW…0.8 W |
Response time |
|
Response time (programmable) | 0.33…60 s |
Voltage drop | 8.0 VDC |
Warm-up time | 5 min. |
Programming | Loop Link |
Signal / noise ratio | Min. 60 dB |
Accuracy | Better than 0.1% of sel. range |
Signal dynamics, input | 19 bit |
Signal dynamics, output | 16 bit |
Effect of supply voltage change | < 0.005% of span / VDC |
EMC immunity influence | < ±0.5% of span |
Input specifications
Common input specifications |
|
Max. offset | 50% of selected max. value |
RTD input |
|
RTD type | Pt100, Ni100, lin. R |
Cable resistance per wire | 10 Ω (max.) |
Sensor current | > 0.2 mA, < 0.4 mA |
Effect of sensor cable resistance (3-wire) | < 0.002 Ω / Ω |
Sensor error detection | Yes |
Linear resistance input |
|
Linear resistance min….max. | 0 Ω…10000 Ω |
Output specifications
Current output |
|
Signal range | 4…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ (Vsupply – 8) / 0.023 [Ω] |
Load stability | ≤ 0.01% of span / 100 Ω |
Sensor error indication | Programmable 3.5…23 mA |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Common output specifications |
|
Updating time | 135 ms |
of span | = of the presently selected range |
I.S. / Ex marking
ATEX | II 3 G Ex nA [ic] IIC T6…T4 Gc, II 3 G Ex ec [ic] IIC T6…T4 Gc, II 3 G Ex ic IIC T6…T4 Gc, II 3 D Ex ic IIIC Dc |
IECEx | Ex nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc |
CSA | Cl. I, Div. 2, Gp. A, B, C, D T6…T4, Ex nA[ic] IIC T6…T4 Gc |
INMETRO | Ex nA [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
DNV Marine | TAA0000101 |
ATEX | DEKRA 20ATEX0106X |
IECEx | DEK 20.0062X |
CSA | 1125003 |
INMETRO | DEKRA 16.0014 X |
EAC Ex | RU C-DK.HA65.B.00355/19 |